Dayton 1UG91C Operations Instructions

Browse online or download Operations Instructions for Vacuum cleaners Dayton 1UG91C. Dayton 1UG91C Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
E
N
G
L
I
S
H
E
S
P
A
Ñ
O
L
F
R
A
N
Ç
A
I
S
Dayton
®
Wet/Dry Vacuum
Operating Instructions & Parts Manual 6AKY2
Please read and save these instructions. read carefully before attemPting to assemble, install, oPerate or maintain
the Products described. Protect yourself and others by observing all safety information. failure to comPly with
instructions could result in Personal injury and/or ProPerty damage! retain instructions for future reference.
Form 5S6688
Printed in U.S.A.
07985
Version 1
01/2013
87548-46
®
Never operate this unit when
flammable materials or
vapors are present because
electrical devices produce
arcs or sparks that can cause
a fire or explosion. NEVER
OPERATE UNATTENDED!
When using an electrical appliance, basic
precautions should always be followed
including the following:
READ ALL INSTRUCTIONS BEFORE USING
THIS APPLIANCE.
COMMERCIAL / INDUSTRIAL USE
Description
Dayton wet/dry vacuum cleaners are for vacuuming wet and dry non-combustible materials.
Equipped with powerful, permanently lubricated, single-stage by-pass motors. Features: motor
housing, blower port, long power cord, convenient on-board tool storage, rugged dent resistant,
rust proof plastic tank. Includes versatile deluxe accessory make-up and efficient filtration. cULus
Specifications
Tank Tank Electrical Static Air
Model Style Capacity Rating Pressure Movement Weight Filters
6AKY2 Plastic 10 Gal. 120V, 60 Hz 60" 195 cfm 21 lbs Cartridge and
(38 liters) AC 12 Amps (152.9 cm) (5.5m
3
/min) (9 .5 kg) Collection Bag
ALWAYS WEAR
EYE PROTECTION
IMPORTANT SAFETY INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY:
1. Do not leave appliance when plugged in.
Unplug from outlet when not in use and
before servicing. Connect to a properly
grounded outlet only. See Grounding
Instructions.
2. Do not expose to rain–store indoors.
3. Do not allow to be used as a toy. Close
attention is necessary when used by or
near children.
4. Use only as described in this manual.
Use only Manufacturer’s recommended
attachments.
5. Do not use with damaged cord or plug. If
appliance is not working as it should, has
been dropped, damaged, left outdoors or
dropped into water, return it to a service
(6AKY2)
center.
6. DO NOT: pull or carry by
cord, use cord as a handle,
close a door on cord or pull
cord around sharp edges or
corners. Do not run appliance
over cord. Keep cord away
from heated surfaces.
7. Do not unplug by pulling on
cord. To unplug, grasp the
plug, not the cord.
8. Do not handle plug or appliance with wet
hands.
9. Do not put any object into openings. Do
not use with any openings blocked; keep
free of dust, lint, hair and anything that may
reduce air flow.
10. Keep hair, loose clothing, fingers and all
parts of body away from openings and
moving parts.
11. Do not pick up anything that is burning or
smoking, such as cigarettes, matches or
hot ashes.
12. Do not use without dust bag and/or filters
in place.
13. Turn off all controls before unplugging.
14. Use extra care when cleaning on stairs.
15. Do not use to pick up flammable or
combustible liquids such as gasoline or use
in areas where they may be present.
16. Do not use your cleaner as a sprayer of
flammable liquids such as oil base paints,
lacquers, household cleaners, etc.
17. Do not vacuum toxic, carcinogenic,
combustible or other hazardous materials
such as asbestos, arsenic, barium,
beryllium, lead, pesticides, or other health
endangering materials. Specially designed
units are available for these purposes.
18. Do not pick up soot, cement, plaster or
drywall dust without cartridge filter and
collection filter bag in place. These are
very fine particles that may pass through
the foam and affect the performance of
the motor or be exhausted back into the
air. Additional collection filter bags are
available.
19. Do not leave the cord lying on the floor
once you have finished the cleaning job. It
can become a tripping hazard.
20. Use special care when emptying heavily
loaded tanks.
21. To avoid spontaneous combustion, empty
tank after each use.
22. The operation of a utility vac can result
in foreign objects being blown into eyes,
which can result in eye damage. Always
wear safety goggles when operating
vacuum.
23. STAY ALERT. Watch what you are
doing and use common sense. Do not
use vacuum cleaner when you are tired,
distracted or under the influence of drugs,
alcohol, or medication causing diminished
control.
24. WARNING! Do NOT use this vacuum
cleaner to vacuum lead paint debris
because this may disperse fine lead
particles into the air. This vacuum
cleaner is not intended for use under EPA
Regulation 40 CFR Part 745 for lead paint
material cleanup.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Wet/Dry Vacuum

ENGLISHESPAÑOLFRANÇAISDayton® Wet/Dry Vacuum Operating Instructions & Parts Manual 6AKY2Please read and save these instructions. read carefully

Page 2

2ENGLISHDayton Operating Instructions and Parts ManualDayton® Wet/Dry Vacuum 6AKY2SAVE THESE INSTRUCTIONSDO NOT LEAVE VACUUM UNATTENDED WHEN IT IS PL

Page 3 - UNATTENDED!

3ENGLISH®Model 6AKY2Dayton Operating Instructions and Parts Manualwhich can cause a fire or explosion - do not use at filling stations or anywhere gas

Page 4

4ENGLISHDayton Operating Instructions and Parts ManualDayton® Wet/Dry Vacuum 6AKY2IF ANY OF THE MOTOR HOUSING PARTS SHOULD BECOME DETACHED OR BROKEN,

Page 5

5ENGLISH®Model 6AKY2Dayton Operating Instructions and Parts ManualANY OTHER ELECTRICAL COMPONENTS, OPERATION SHOULD BE DISCONTINUED IMMEDIATELY TO AVO

Page 6

6ENGLISHDayton Operating Instructions and Parts ManualDayton® Wet/Dry Vacuum 6AKY2Troubleshooting Chart Parts/accessories Packed in tank Check in

Page 7

For Repair Parts, call 1-800-323-062024 hours a day – 365 days a yearPlease provide following information:-Model number-Serial number (if any)-Part de

Page 8

Manufactured for Dayton Electric Mfg. Co.Lake Forest, Illinois 60045 U.S.A.® 6AKY2Dayton Operating Instructions and Parts

Comments to this Manuals

No comments