Dayton Installation, Operation, Maintenance and Parts Manual
Models 1RVT7 and 1RVT8
Wiring Diagrams
Figure 3.1 - 120V
Amp draw:
.25 starting
.24 running
Lighting Instructions:
1. Rotate heater’s valve knob to “ON” position.
2. Close electrical circuit (usually thermostat).
3. If the heater fails to light, turn “OFF” gas, open
electrical circuit and wait 5 minutes before
repeating.
Shutdown Instructions:
1. Open electrical circuit (usually thermostat).
2. Turn off electrical power if service is to be
performed.
3. Rotate heater’s valve knob to “OFF” position.